ISSUE #10 · WEEKLY EDITION · NEWS, LITERATURE & JOBS · NOV 23, 2026
Welcome to FlowCytoNews, the week in flow cytometry: news, papers and jobs. This week: the FDA's decision file for Waters' BD OneFlow tubes, which lists the markers and the analyzer they're cleared on; Standard BioTools shareholders approved the $5.5 million sale of its mass cytometry business; and a survey of 277 flow core specialists in 32 countries found 40% considering leaving their jobs. Tell us what we missed — hit reply.
Correction: last week we expanded BD OneFlow LST as "lymphoid screening tube." The FDA's decision summary calls it the Lymphoid Survey Tube.
■ Industry Moves
The FDA file on OneFlow: a 12-marker and an 8-marker tube, cleared on FACSLyric with its violet laser added
The FDA's decision summary for the BD OneFlow clearance that Waters announced on Nov 10 (K260215) fills in what the company's release left out. The clearance letter, addressed to BD Biosciences, is dated Oct 20; the submission arrived on Sept 14. It is one bundled 510(k) covering three products. The LST tube carries 12 markers: CD3, CD4, CD5, CD8, CD19, CD20, CD38, CD45, CD56, Igκ, Igλ and TCRγ/δ. The B-CLPD T1 tube carries 8: CD10, CD19, CD20, CD23, CD43, CD45, CD79b and CD200, and is cleared for use alongside the LST. Both are cleared for peripheral blood in EDTA or heparin, bone marrow in K2 EDTA, and lymph node. The third product is the BD FACSLyric analyzer in 8-, 10- and 12-color configurations. Its earlier IVD clearance covered up to six fluorescence channels on the blue and red lasers; this one adds the violet laser and raises the count to eight. The filing also adds FACSuite Clinical software version 1.5, with OneFlow acquisition and analysis templates, and three new compensation bead reagents. The predicate is Beckman Coulter's ClearLLab 10C panels, cleared on Navios. The clinical study compared OneFlow with ClearLLab 10C against each site's final diagnosis. The public summary gives no specimen or site counts and no sensitivity or specificity figures, listing every endpoint only as "PASSED."
▪ FDA · letter dated Oct 20 · K260215 decision documents (PDF)
Why it matters: The comparison that got OneFlow cleared was against another cleared kit, not against the lab-developed lymphoma tubes most US labs actually run. So it tells you OneFlow matches ClearLLab, not that it matches your assay; that bridging work is still yours. The FACSLyric change reaches further than OneFlow: the analyzer's IVD indication now covers the violet laser and eight fluorescence channels. And the 96.3% sensitivity and 98.2% specificity for CLL come from Waters' release, not this summary, so ask for the full study before you budget validation time.
At a special meeting on Nov 19, Standard BioTools stockholders approved all proposals for its merger with Treeline Biosciences and for the sale of its mass cytometry business to Element Biosystems, LLC, a vehicle formed by GMT Venture Partners. They also approved a reverse stock split and renaming the company Treeline Biosciences, Inc. The merger proxy puts the sale price at $5.5 million on a cash-free, debt-free basis, subject to adjustments, and says Standard BioTools will provide transition services to Element after closing. The proxy describes Element as focused on mass cytometry, single-cell and spatial biology, and says it plans to work with Core Quantum Technologies and other early-stage biotechs on mass cytometry in drug discovery. The company expects the Treeline merger to close in the fourth quarter of 2026, with the mass cytometry sale closing at about the same time. Neither the release nor the proxy passages we read mention CyTOF or Hyperion customers, service contracts or staff.
▪ Standard BioTools · Nov 19 · 8-K release · merger proxy
Why it matters: $5.5 million for the business that sells CyTOF and Hyperion is a clear statement of what standalone mass cytometry is worth today. For a core that owns one, nothing changes until closing, but the open questions are service contracts, reagent supply and who answers the phone after the transition services end. Get those answers in writing before your next service renewal.
Quick hits
ApogeeFlow added MieSquiggle-3D (Cat# 1492), an extension of its light-scatter calibration that reports particle size in nanometres and a refractive index from small-, medium- and large-angle scatter, using particle populations of known refractive index (the page gives 1.430 and 1.380 as examples). The announcement is dated November 2026 and doesn't list supported instruments, size range or price. — ApogeeFlow
Agilent reported fiscal fourth-quarter revenue of $2.04 billion, up 9.6% (8.3% core), for the quarter ended Oct 31. The release doesn't mention cell analysis. — 8-K, Nov 23
Nothing new we could confirm this week from Beckman Coulter, Thermo Fisher, Miltenyi or Sysmex.
■ The Literature
No new OMIP entered PubMed this month. Papers below went online Nov 12–23 and weren't in last week's edition.
A survey of 277 flow core specialists: 85% would choose a different job title, and 40% are thinking about leaving
Eva Orlowski-Oliver (Research Flow Core, Peter MacCallum Cancer Centre, Melbourne), Jochen Behrends (Research Center Borstel, Germany) and Pat Metharom (Curtin University, Perth) ran a 29-question anonymous survey of 277 flow cytometry specialists in shared resource labs across 32 countries; two-thirds worked in the US, UK, Germany or Australia. 85.2% had an official job title that didn't match the one they would pick. Among them, 109 (46.2%) wanted a title that names flow cytometry and 92 (39.0%) wanted a management or leadership title. Respondents held 63 different official titles, and of the 88 who preferred "Flow Cytometry Specialist," 5 actually had it. The most common work done outside the formal role without extra pay was student supervision (32.5% of respondents), research leadership (30.7%) and experimental research (27.4%). 40% were considering or actively seeking to leave their current role, about the same whether or not their title matched. Recognition and pay were among the top factors for both satisfaction and dissatisfaction. 80% rated structural and institutional factors as strong barriers to advancement (4 or 5 on a 5-point scale), against 19% for demographic factors. 55% had never heard of the Technician Commitment, a framework meant to improve recognition and career development for technical staff; in the US the figure was 76% and in Germany 81%. The abstract doesn't say how respondents were recruited or what the response rate was. No industry co-authors.
▪ Cytometry Part A · Nov 19 · 10.1002/cyto.a.70079
Why it matters: If you run a core, or manage the people who do, this is the retention risk with numbers on it. The fix the authors propose costs almost nothing: a title that names flow cytometry and a job description that matches the supervision, research and management the person already does. Read the 40% as a warning sign rather than a turnover rate, since we don't know who chose to answer.
In PNH, flow found C3d on red cells that the DAT missed, and the level tracked reticulocytes
Anna Zaninoni and Wilma Barcellini (Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan) measured C3d on red cells by direct antiglobulin test and by high-sensitivity flow in 27 PNH patients between March 2024 and February 2025: 14 with hemolytic PNH and 13 with PNH associated with MDS or aplastic anemia. Four were untreated; the rest were on terminal (16), proximal (6) or combined (1) inhibitors. The DAT was positive for C3d in 6 of 27. Flow found C3d on more than 5% of red cells in a further 29% of DAT-negative patients. Above that 5% threshold, patients had lower hemoglobin (10.4 vs 12.7 g/dL) and higher reticulocytes (198 vs 95 ×10⁹/L); only the reticulocyte difference held after correction for multiple testing. C3d correlated with reticulocyte count (rho 0.83). As a marker of clinically significant extravascular hemolysis, flow C3d had an AUC of 0.69 (95% CI 0.42–0.91), with an exploratory cutoff of 2.4% C3d-positive among CD59-negative red cells; the DAT's sensitivity was 0.25. It is a single-center exploratory study. No industry co-authors.
▪ Mayo Clin Proc Innov Qual Outcomes · Nov 12 · 10.1016/j.mayocpiqo.2026.100779
Why it matters: As more PNH patients go onto complement inhibitors, the question shifts from whether the clone is there to why a treated patient is still anemic, and here the DAT missed most of the answer. A lab already running high-sensitivity PNH flow has the instrument and the gating to add C3d. But an AUC of 0.69 with a confidence interval reaching down to 0.42, in 27 patients, is a reason to start collecting data, not to put a cutoff on a report.
A Montevideo hospital monitors the CAR-T cells it makes; peak levels ran 14% to 44% of T cells in five patients
Marcela Barrios and Luis Castillo (Fundación Pérez Scremini, Montevideo) describe the flow monitoring behind Uruguay's academic anti-CD19 CAR-T program, which manufactures cells on site on a CliniMACS Prodigy. CAR-T cells were detected with a biotinylated CD19 CAR detection reagent and anti-biotin PE in a six-color tube (7-AAD, CD45, CD14, CD3, CD4, CD8) on a Beckman Coulter DxFLEX, acquiring at least 100,000 events; a separate 10-color tube tracked B-cell aplasia. Blank, detection and quantification limits of 8, 13 and 22 events were taken from published criteria rather than recalculated locally. In six paired acquisitions from two healthy-donor products, CVs for CAR-positive T cells ran 1.46% to 2.79%. In the five patients treated so far (four children, one young adult), CAR-T levels peaked between day 7 and day 16 at 13.9% to 43.78% of T cells, and B cells fell in all five by the first post-infusion check and stayed absent or very low through follow-up of 118 to 153 days. The study was not designed to link CAR-T kinetics to response or toxicity, and the article doesn't name the CAR construct or give the total number of samples. The authors report no funding and no conflicts; the detection reagent is Miltenyi's and the analyzer Beckman Coulter's.
▪ Front Hematol · Nov 16 · 10.3389/frhem.2026.2007169
Why it matters: Point-of-care CAR-T programs are spreading to places without a central lab to lean on, and this is what a minimal, runnable monitoring assay looks like: one commercial detection reagent, six colors, a clinical analyzer. The gaps are the ones last week's German-Austrian-Swiss harmonization study warned about. The limits are borrowed rather than measured on this instrument, and the peaks are reported as a share of T cells, which can't be pooled with centers that report cells per microliter. If you're setting up something similar, measure your own limits and report concentration from day one.
Silica nanoparticles open zirconium, niobium, hafnium and tantalum channels for mass cytometry
Xiaochong Li and Mitchell Winnik (University of Toronto), with co-authors in Nanjing and Lisbon, built mesoporous silica nanoparticles engineered with deferoxamine that carry metals standard mass tags rarely use (Zr, Hf, Nb and Ta) at about 10,000 metal atoms per particle, then conjugated them to antibodies. Nb-, Hf- and Ta-loaded CD8a probes resolved CD8-positive T cells at as few as 30 particles per cell. In a 30-plex PBMC panel stained alongside commercial Maxpar reagents, a Ta-loaded CD25 probe recovered CD25-high CD127-low Treg-like cells at levels comparable to the matching Maxpar reagent while using about 35-fold less antibody. The abstract doesn't give spillover into neighboring channels or the number of donors tested. One co-author is from Standard BioTools Canada (Markham, Ontario); see the sale item in Industry Moves.
▪ Angew Chem · Nov 17 · 10.1002/anie.1099418
Why it matters: Mass cytometry's practical limit is how many metal channels have usable reagents, and this adds four elements that are rarely used. The timing is awkward: reagent development is part of what Element is buying for $5.5 million, so whether chemistry like this reaches a catalog now depends on the new owner.
Also out
A cleanup step for Infinity Flow data. Hsiao-Chi Liao, Terence Speed and Agus Salim (University of Melbourne, WEHI and others) released mapfx.norm, part of the MAssively Parallel Flow cytometry Xplorer R package. It removes background noise and batch effects from massively parallel cytometry experiments, which measure more than 200 surface proteins, before machine learning imputes the exploratory markers. The authors report it beat alternatives at keeping biological signal and imputing unmeasured markers; the abstract gives no figures. No industry co-authors. — NAR Genom Bioinform · Nov 23 · 10.1093/nargab/lqag133
Flow cytometry on lymph node fine-needle aspirates. William Sewell (St Vincent's Hospital Sydney), Anna Porwit and co-authors wrote a review to accompany the first WHO Reporting System for Lymph Node, Spleen and Thymus Cytopathology, covering adequacy criteria for FNA samples sent for flow, ways to estimate blood contamination, and TRBC1 and TRBC2 for assessing T cells. No industry co-authors. — Acta Cytol · Nov 19 · 10.1159/000550290
Basophil activation testing, reviewed. Francesco Catamerò (University of Florence), Mohamed Shamji (Imperial College London) and 14 co-authors cover the flow-based BAT across food, drug, venom and respiratory allergy, and list what holds back wider use: no standard protocols, validated cut-offs or reference materials, non-releasers, and the need for fresh blood. No industry co-authors. — Allergy · Nov 22 · 10.1111/all.70573
A BCMA/CD19 CAR-T in relapsed myeloma, with flow MRD at 10⁻⁵. Hua Jiang and Weijun Fu (Shanghai Fourth People's Hospital) treated 24 patients with KQ-2003. Of 19 who were MRD-positive at baseline by next-generation flow, 12 (63.2%) were MRD-negative by month 6; median PFS was 24.0 months. Several co-authors are from Novatim Immune Therapeutics and Shanghai DIAN Medical Laboratory. — J Hematol Oncol · Nov 18 · 10.1186/s13045-026-01870-y
A 23-marker panel for CAR-NK cells. Meric Birben and Wilfred Germeraad (Maastricht UMC+) published a protocol for knocking a CAR into the AAVS1 locus of expanded NK cells and phenotyping them with a 23-marker flow panel that includes CAR detection. One co-author is from CiMaas BV. — STAR Protoc · Nov 20 · 10.1016/j.xpro.2026.104989
New on ClinicalTrials.gov
A 1,290-patient AML trial that sorts patients by flow MRD after one cycle. The French ALFA-FILO intergroup's BIG-2 umbrella trial (phase 3, sponsor University Hospital Toulouse) will enroll adults aged 18–60 with newly diagnosed AML at 55 listed French sites, starting Jan 4, 2027. After one cycle of 7+3, patients who are refractory or have marrow MRD of 0.1% or more by multiparameter flow are randomized to high-dose cytarabine with or without venetoclax, with flow MRD response after one cycle as the primary endpoint. Patients below 0.1% (or below the limit of detection) go into a single-arm MRD-guided program with overall survival as the endpoint. A separate FLT3-ITD arm compares quizartinib with midostaurin, read by PCR-NGS MRD. Primary completion is listed as Dec 31, 2035. — NCT07948122
Stopping myeloma maintenance on two years of negative flow MRD. A pragmatic multicenter study in Latin America (sponsor Hospital Universitario Dr. José E. González) plans to stop maintenance in 62 newly diagnosed myeloma patients in complete or stringent complete response who are MRD-negative by EuroFlow-based next-generation flow (or equivalent) on two marrow tests at least 12 months apart, with negative PET/CT. Patients are then followed with flow MRD (sensitivity 10⁻⁵ or better) every six months, and maintenance restarts if MRD returns or the disease relapses. The primary endpoint is the share with MRD return, relapse or death within 24 months. Not yet recruiting; the record lists no sites yet. — NCT07947927
Why it matters: In both trials a flow MRD number decides treatment: which arm an AML patient enters, and whether a myeloma patient stops therapy. That puts each site's MFC assay, its limit of detection and how well it agrees with the other labs, on the critical path. If your lab may run samples for either, start the inter-lab comparison before the first patient enrolls.
Preprints
Not peer reviewed. The preprint records show only the corresponding author's affiliation.
Elflow: automated QC and self-supervised learning for high-dimensional cytometry. Yogesh Kalakoti and colleagues pair automated quality control with a self-supervised model (VICReg) that learns single-cell representations without manual gating, tested on four public datasets. On the 22-channel OMIP-030 spectral panel it beat classical baselines at unsupervised clustering and reproduced manual gating hierarchies; on the Levine-13 CyTOF panel, plain PCA did as well as the deep models; it detected AML across instruments in FlowCAP-II and stratified AIDS-free survival in FlowCAP-IV. The abstract gives no accuracy figures. The corresponding author is at Elucidata Corporation. — bioRxiv · Nov 18 · 10.64898/2026.11.17.767309
Peanut allergy testing in one flow tube. Menno van Zelm (Monash University) and colleagues added six fluorescent peanut allergen tetramers to a cytometric basophil assay (CytoBas) and a memory B-cell panel, tested in 27 peanut-allergic adults and 15 controls. CytoBas matched or beat component IgE ELISAs (AUC 0.79–1.0 vs 0.78–0.9), and Ara h 2 separated every patient from every control. Patients had expanded type 2 memory B cells specific for Ara h 1, 2 and 3. — medRxiv · Nov 20 · 10.64898/2026.11.18.26368397
■ Hiring
Company | Role | Location · pay |
|---|---|---|
Precision for Medicine | Frederick, MD · $110,700–$166,100 (estimated) | |
IQVIA Laboratories | Valencia, CA · $64,200–$133,600 base | |
Precision for Medicine | Frederick, MD · $89,000–$127,500 (estimated) | |
Thermo Fisher Scientific | Technical Application Scientist II – Flow Panel Design (via Germany's federal job board) | Darmstadt, Germany, partly remote · pay not shown |
Versiti | Wauwatosa, WI · pay not shown | |
Clinical Pathology Laboratories (Sonic Healthcare USA) | Austin, TX · pay not shown | |
Labcorp | Clinical Laboratory Technologist, Flow Cytometry (trainee; new grads welcome) | Durham, NC (RTP), Thu–Sun · pay not shown |
Quest Diagnostics | Lewisville, TX · from $17.71/hour |
Precision for Medicine also had a senior scientific director flow role open in Frederick when we checked last week.
What did we miss? Hit reply — corrections run at the top of the next edition. If a colleague runs a flow core, a clinical flow lab or a CAR-T monitoring program, forward this to them.