Welcome to FlowCytoNews. Most weeks we send three editions: Monday is The Literature (new papers), Wednesday is On the Calendar (events and deadlines) and Friday is Industry Moves (companies and jobs). This week it's one combined update: the news, the papers and the jobs. In it: the FDA cleared Waters' BD OneFlow LST and B-CLPD T1 tubes for B-cell lymphoma workups, with U.S. sales starting in spring 2027; the U.S. International Trade Commission opened an investigation into Cytek's patent complaint against Beckman Coulter's spectral detection products; and a German-Austrian-Swiss group showed that a shared CAR-T counting workflow cut lab-to-lab spread from as high as 158% CV to at most 69%. Tell us what we missed — hit reply.

■ Industry Moves

FDA clears Waters' OneFlow LST and B-CLPD T1 tubes for B-cell lymphoma; U.S. sales start spring 2027

Waters said on Nov 10 that the FDA has given 510(k) clearance to two dried-reagent tubes from the BD OneFlow line, the LST (lymphoid screening tube) and the B-CLPD T1, to aid in identifying B-cell non-Hodgkin lymphoma, including CLL. For CLL identification, Waters reports 96.3% sensitivity and 98.2% specificity. The company says the OneFlow approach removes 95% of manual steps compared with building liquid cocktails; that comparison comes from an internal Waters study. The tests are open for preorder and, in Waters' words, "will be commercially available in the U.S. in spring 2027." The rest of the OneFlow line, for myeloma, ALL and AML, is sold as CE-IVD reagents and is based on EuroFlow Consortium work. The release does not list the markers, the cleared instrument platforms or the size of the clinical study. BD remains legal manufacturer until regulatory transfers to Waters are complete.

▪ Waters · Nov 10 · Waters news release (PDF)

❝

Why it matters: Most U.S. clinical flow labs run lymphoma screening as lab-developed tests on cocktails they build and validate themselves. An FDA-cleared, EuroFlow-derived tube changes that calculation, especially for smaller hospital labs where validation and pipetting time are the real costs. The catch is the spring 2027 date and the missing details: before anyone budgets for it, ask Waters which instruments the clearance covers, what the study population was, and what a tube costs next to your current reagent spend.

ITC opens an investigation into Cytek's patent complaint against Beckman Coulter's spectral detection products

The U.S. International Trade Commission voted on Nov 10 to open a Section 337 investigation (337-TA-1528) based on a complaint Cytek filed on Oct 8 and supplemented on Oct 26. The respondents are Beckman Coulter, Inc. (Brea, California) and Beckman Coulter Biotechnology (Suzhou). Cytek asserts claims of three U.S. patents (12,754,128; 12,487,167; and 10,739,245) and asks for a limited exclusion order and cease-and-desist orders. The ITC notice names Beckman's mosaic 88 and mosaic 63 products among the optical detection systems at issue. The ITC says opening the case is not a decision on the merits; a judge will hold a hearing and issue an initial determination, and the Commission will set a target completion date within 45 days. This sits alongside an older fight running the other way: Beckman sued Cytek in Delaware, and on Aug 21 a jury found in Cytek's favor on three of four claims and found infringement under the doctrine of equivalents on the fourth, which Cytek says it is challenging. We found no public statement from Beckman Coulter on the ITC case.

❝

Why it matters: An ITC case is about imports, and the second respondent is Beckman's Suzhou site, so the remedy Cytek wants would hit products made there and shipped into the U.S. Nothing changes for a lab today; these cases usually take more than a year. But a lab weighing Beckman's modular spectral add-ons against a Cytek system now has a legal question in the mix, and it's fair to ask both vendors in writing about supply and service commitments if the case goes against them.

By the numbers

Third-quarter results that landed after our last Industry Moves (Oct 23).

Company

What

Number

vs. prior / guidance

Source

Cytek

Q3 revenue

$53.2M (+2%)

Product $37.2M, down from $38.1M; service $16.1M, up from $14.2M; FY26 guide $208–211M kept

Cytek

Installed base

4,073 instruments

140 added in Q3; U.S. revenue +12%

Waters

Biosciences Division revenue

$396M

vs. $387M; reagents up high single digits, research and clinical both

Revvity

Life Sciences revenue

$380M

vs. $343M; pro forma organic +9%; release doesn't break out reagents

❝

Why it matters: Cytek's service line grew 13% while instrument-heavy product revenue fell, which is what happens when an installed base matures faster than new placements. Waters' own reagent line grew high single digits, so the big incumbent isn't losing the consumables pull-through. Cytek's full-year guide needs about a $64M fourth quarter, so watch its Q4 instrument number most.

Quick hits

  • Nothing new we could confirm in the window from Agilent (its NovoStation sample-prep launch was Oct 1), Thermo Fisher or Miltenyi.

■ The Literature

No new OMIP in Cytometry Part A turned up in our search since our Nov 2 edition. Papers below went online Nov 2–17.

A shared CAR-T counting workflow cut lab-to-lab spread from up to 158% CV to at most 69%

Gerulf Hänel and Marion Subklewe (LMU University Hospital, Munich), with centers across Germany, Austria and Switzerland, built and harmonized a dual-platform flow workflow for counting CD19 CAR-T cells in blood, using a PE-conjugated FMC63 idiotype antibody and a fixed gating strategy with absolute leukocyte counts. Limits of detection and quantification were 0.02% and 0.03% of CD45+ events (0.9 and 1.5 CAR-T cells/µL), and intra-assay CVs were typically under 10%. Sample age mattered: EDTA blood analyzed three days after collection underestimated CAR-T concentration about fourfold, which a cell-preservative tube markedly improved. In four external quality assessment rounds (seven samples, 31 centers), CVs ran from 16% to 92% depending on CAR-T level; labs using the harmonized workflow came in at 4.9–69% CV, against 26–158% for other methods. A co-author is from Miltenyi Biotec; MLL Munich Leukemia Laboratory and two other private diagnostic labs are also among the authors.

▪ Cytometry Part B · Nov 5 · 10.1002/cyto.b.70086

❝

Why it matters: CAR-T expansion is read as a predictor of response and toxicity, but if one center's count can be off from another's by more than 100% CV, pooled trial and registry data mean little. The paper puts most of that spread on method, not instrument. The fourfold loss in three-day-old EDTA blood is the line every lab receiving shipped samples should read twice. See Bench Notes.

ChatGPT read leukemia dot plots for 560 patients and agreed with hematologists 79% of the time

Mesut Göçer and Erdal Kurtoğlu (Antalya City Hospital and Antalya Training and Research Hospital, Turkey) uploaded de-identified PDF dot plots from a three-tube, 28-antibody acute leukemia panel for 560 patients to ChatGPT (GPT-5.5) with one standard prompt; no FCS files were provided. Against two hematologists' consensus, the model's diagnostic accuracy across five categories (no pathology, MDS, AML, B-ALL, T-ALL) was 78.8% (95% CI 75.2–81.9%), Cohen's κ 0.712. It disagreed systematically on AML, T-ALL and no pathology. Blast estimates correlated (r = 0.818) but ran high by 3.92 percentage points on average. For hematogones it reached 89.5% accuracy with 70.3% sensitivity. No industry co-authors.

▪ Cytometry Part B · Nov 11 · 10.1002/cyto.b.70097

❝

Why it matters: One in five wrong is not a second reader, and the misses fall exactly where they cost most: AML versus T-ALL, and calling hematogones blasts. A 4-point upward bias on blast counts matters at the 20% AML threshold. The useful finding is narrower: a general model reading only static plots gets most of the way there, which tells you a purpose-built tool working from FCS files should do far better.

Moving a trial immunophenotyping panel from Gallios to DxFLEX broke the absolute counts

Lia Mogge and Anna-Jasmina Donaubauer (Uniklinikum Erlangen) transferred a detailed whole-blood immunophenotyping assay used in clinical trials from Beckman Coulter's Gallios to its successor, the DxFLEX, which has similar lasers and filters. Every antibody and population could be measured on the new instrument, but the calculated absolute concentrations of cell populations differed between the two. The authors conclude the values can't be compared and that switching this assay mid-trial isn't feasible; they call for parallel measurements whenever a complex assay moves. The abstract gives neither the size of the differences nor the number of samples. No industry co-authors.

▪ Cytometry Part A · Nov 9 · 10.1002/cyto.a.70078

❝

Why it matters: "Successor instrument, same optics" is how most core replacements get sold, and this is a same-vendor upgrade that still didn't carry absolute counts across. If you run longitudinal trial samples, keep the old cytometer running until a bridging study is done.

Mayo's high-resolution blood M-protein test called 89% of myeloma patients positive where marrow flow called 51%

Ryan Pearce and David Murray (Mayo Clinic, Rochester) validated HiRes Mass-Fix, a liquid chromatography quadrupole time-of-flight method for low-level M-protein, and compared it with bone marrow next-generation flow MRD in 174 patients. It found M-protein in 41 of 58 samples negative by the standard MALDI-TOF Mass-Fix, raising blood positivity from 62% to 89% against 51% by marrow flow. Blood–marrow agreement fell from 71% (κ 0.43) to 58% (κ 0.15), driven by blood-positive, marrow-negative cases, and IgG was overrepresented among them (68% vs 45%). The authors suggest IgG recycling may explain the gap and say serial measurements are needed to tell residual protein from ongoing production. No industry co-authors.

▪ Clin Chem Lab Med · Nov 11 · 10.1515/cclm-2026-1525

❝

Why it matters: More sensitive blood testing doesn't make marrow flow MRD obsolete; here it made the two disagree more. Until serial data sort out IgG half-life from live disease, a blood-positive, NGF-negative patient is a question, not a relapse.

Also out

  • Anti-CD20 therapy left CD20-negative CLL in a third of patients with MRD. Tamasine Stewart and Kah Lok Chan (Peter MacCallum Cancer Centre, Melbourne) reviewed 60 patients after fixed-duration venetoclax with obinutuzumab or rituximab; 10 of 29 (34%) with MRD at end of treatment had lost CD20 by flow, NOTCH1 variants were more common in them (5 of 10), and all five followed over time stayed CD20-negative for 12 to 39 months. — Br J Haematol · Nov 16 · 10.1111/bjh.70948

  • Real-world CLL MRD at a median detection limit of 0.0032%. Jana Mihalyova and Roman Hajek (University Hospital Ostrava) ran 749 blood and 64 marrow samples from 177 patients with 8-color ERIC flow; undetectable MRD in newly diagnosed patients went with longer PFS (median 58.0 vs 34.7 months, HR 2.28) but not in the relapsed group, where 38% were on continuous BTK inhibitors. Two co-authors are from Spadia Lab. — Front Oncol · Nov 2 · 10.3389/fonc.2026.1918537

  • CD8+CD38+HLA-DR+ T cells help rule in adult HLH. Saikat Mondal and Jyoti Kotwal (Sir Ganga Ram Hospital, Delhi) studied 106 adults with cytopenias and high ferritin (50 with HLH); the double-positive subset had AUC 0.824, with 78% sensitivity and 81% specificity above 16.71% of CD8 T cells, while single-positive subsets didn't discriminate. A clinical HScore did better (AUC 0.970). — Cytometry Part B · Nov 17 · 10.1002/cyto.b.70098

  • A random forest matched manual PNH gating, down to about 50 clone cells. Felipe Magalhães Furtado (Sabin Diagnóstico e Saúde, Brasília) and Adamara Felício (University of São Paulo) trained models on FLAER, CD15, CD45, CD64 and CD157 data; the random forest agreed 100% qualitatively with manual analysis, a neural network 45%. Spiked in, the forest caught all samples at 100 or 200 PNH cells, 3 of 5 at 50 and none at 25. Most authors are from Sabin Diagnóstico e Saúde, a private lab company. — Cytometry Part B · Nov 3 · 10.1002/cyto.b.70092

  • An R package reads FlowJo v11 workspaces. Bernd Jagla and Milena Hasan (Institut Pasteur, Paris) released CyFj11, which imports FlowJo v11 gating hierarchies into R and writes R-defined gates back; population counts matched FlowJo 10 and 11 with Pearson r above 0.99. Free on GitHub. No industry co-authors. — Cytometry Part A · Nov 17 · 10.1002/cyto.a.70075

  • A reply to St Jude on interpretive uncertainty. A letter from Marc Sorigue and Jordi Petriz (Germans Trias i Pujol Research Institute, Badalona) responding to Mead et al. on making interpretive uncertainty visible in clinical flow reports. No abstract online, so title only. — Cytometry Part B · Nov 14 · 10.1002/cyto.b.70094

■ Hiring

Company

Role

Location · pay

Precision for Medicine

Frederick, MD (onsite) · $203,200–$304,800

Xaira Therapeutics

South San Francisco, CA (5 days onsite) · $140,000–$170,000 plus bonus and equity

Axle, for NIAID's Flow Cytometry Section

Bethesda, MD · $70,000–$80,000

Sony Biotechnology

Germany · pay not shown